omron — Using Sentech STC-M Cameras with AutoVISION and VISIONSCAPE – Supplemental User Guide

3) Running the Job Once the job is programmed, it can be put into Run Mode. The Run Mode screen will display any GigE bandwidth issues. Typically, you will see FIFO errors, or the acquisition will stop. 4) Troubleshooting GigE Cameras In this case, you can go back to the AVP Backplane Debug window. Here you will see what camera is having the issue, and what the issue is. In this case, you can see that there are missing packets. At this point, you should take the following steps. a. Check NIC settings to make sure Jumbo Packets and Receive Buffers are set to max values. If not, shut down Visionscape, and close and exit the AVP Backplane by right clicking on it and selecting close. b.

Check the Registry to see if Packet Size is set to Jumbo Packets (8192 or above). If not, set appropriately. c. If both of these are set correctly, increase the InterPacketDelay. d. Stop the Job, and then create a new Job to read in new values for Packet Size and Interpacket Delay. Repeat process until you can run reliably. Using Sentech STC-M Cameras with AutoVISION and Visionscape Page 15 of 32