MAINTENANCE C. ENGINE FLUID LEAKS 1. Inspect complete engine for signs of fluid leaks. 2. When inspecting around pressure lines and hoses use a stiff piece of cardboard. See Fig- ure 4.13A. 9 REST'D AIR CLEANER CAUTION Never use hands to check for leaks. High pressure fluid leaks will penetrate the skin and cause severe injury. FIGURE 4.13B SK32004021 AIR CLEANER COMPARTMENT RADIATOR COMPARTMENT 4 SK32001033 FIGURE 4.13A SECURE DOOR OPEN D. AIR CLEANER FIGURE 4.13C CAUTION Wear protective glasses or goggles when using com- pressed air. NOTE The air restriction indicator will not signal if the element is torn or if the air cleaner compartment is not sealed prop- erly.
If “REST’D AIR CLEANER” icon is displayed, as in- dicated in Figure 4.13B, inspect, clean, and/or replace the air cleaner elements. FIGURE 4.13D 1. Open engine air cleaner access door and lock open. Use ignition key if door is locked to un- lock it. See Figure 4.13C. 2. Release clamp from the air cleaner cover. See Figure 4.13D. 3. Remove the air cleaner outer element from the housing. See Figure 4.13E. NOTE Replace the Air Filter elements every 1000 hours or when the restricted icon appears on the cluster gauge, which ever comes first. FIGURE 4.13E SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 4-13 RELEASE CLAMP AND COVER REMOVE AIR CLEANER OUTER ELEMENT