Load Cell Module DVP02LC-SL CH1 NET MAX ZERO MOTION CH2 NET ZERO MOTION MAX „ NET LED „ ZERO LED „ MAX LED „ MOTION LED 9.2 Trouble-shooting DVP-PLC Operation Manual 36 LED status Indication Off The current weight is gross weight. Orange light constantly on The current weight is net weight. LED status Indication Off The current weight is not zero point weight. Orange light constantly on The current weight is zero point weight. LED status Indication Off The current weight does not exceed max. weight. Orange light constantly on The current weight exceeds max. weight. LED status Indication Off The current weight is an unstable value.
Orange light constantly on The current weight is a stable value. Abnormality How to correct POWER LED off Check if the power supply is normal. RUN LED off There is problem in internal hardware. Send the module back to factory for repair. ERROR LED on 1. Check the error code in CR#50. 2. Check if the voltage at SEN+ and SEN- is +5V. L.V LED constantly on Check if the input voltage is lower than 18V.