U.S. Department of Defense MIL-STD-810D — vdj6225.tmp (EN)

Downloaded from https://www.everyspec.com MIL-STD-81OD 19 July 1983 CONTENTS - Continued far- aDh 5. TEST METHODS Method No.

500.2 501.2 502.2 503.2 504 505.2 506.2 507.2 508.3 509.2 510.2 511.2’ 512:2 513.3 514.3 515.3 516.3 517 518 519.3 520.G Low Pressure (Altitude) High Temperature Low Temperature Temperature Shock (deleted) Solar Radiation (Sunshine) Rain Humidity Fungus salt Fog 500.2-1 - 500.2-10 501.2-1 - 501,2-18 502.2-1 - 502.2-14 503.2-1 - 503.2-14 505.2-1 - 505.2-18 506.2-1 - 506.2-12 507.2-1 - 507.2-18 508.3-1 - 508.3-16 509.2-1 - 509.2-12 510.2-1 -,.510.2-14 511.2-1 - 511.2-18 512.2-1 - 512.2-8 513.3-1 - 513.3-14 514.3-1 -.514.3-84 515.3-1 - 515.3-16 516.3-1 - 516.3-26 *- Sand and Dust Bxplosive Atmosphere Leakage (Immersion) ,, Acceleration Vibration Acoustic Noise Shock (deleted) (deleted) Gunfire Temperature, Humidity, Vibration, 519.3-1 - 519.3.-18 Altitude Icing/Freezing Rain 520.0-1 - 520.0-28 521.0-1 - 521.0-8 521.0 522 (to be added later) Vibro,-Acoustic,Temperature 523.0 523.0-1 - 523.0-20 6.

6.1 ~~ 6.2 6.3 ~~ 6.4 NOTES 18 18 18 19 19 Intended use. Data requirements International standardization agreement Changes from previous issue TABLES -: 500.2-1 501.2-I Minimum cargo compartment pressures 500.2-4 High temperature cycles, climatic ,. category - hot 501.2-6 High temperature cycles, climatic 501.2-II category -.basic hot 501.2-7 S-ry of high temperature diurnal cycle ranges 501.2-8 Summary of low temperature diurnal 501.2-III 502.2-I ,,, cycle temperature ranges 502.2-5 v