Ethernet Communication Module IFD9506 4.2 Explanations on BR BR#0: Model Name Explanations: 1. Model code of IFD9506 = H’0200. 2. You can read the model code in the program to see if the extension module exists. BR#1: Firmware Version Explanations: The firmware version of IFD9506 is displayed in hex, e.g. H’0100 indicates version V1.00. BR#2: Release Date of the Version Explanations: Displaying the data in decimal form. 10,000s digit and 1,000s digit are for “month”; 100s digit and 10s digit are for “day”. For 1s digit: 0 = morning; 1 = afternoon. Example: 12191 indicates the version released in the afternoon of December 19. BR#4: Communication Format Explanations:
DVP-PLC Application Manual 9 BR# Attribute Content Explanation Default Latched 14 ~ 32 Reserved 33 R/W Returning to default setting 0 No Symbol “R” refers to read only; “R/W” refers to read and write. BR#4 low byte b7 ~ b4 b3 b2 ~ b1 b0 Explanation Reserved Stop bit 0: 1 stop bit 1: 2 stop bits Parity bit 00: None parity bit 01: Odd parity bit 11: Even parity bit Data bit 0: 7 data bits 1: 8 data bits Content 0000 (0) 7-N-1 0011 (3) 8-O-1 1000 (8) 7-N-2 1011 (B) 8-O-2 0001 (1) 8-N-1 0110 (6) 7-E-1 1001 (9) 8-N-2 1110 (E) 7-E-2 0010 (2) 7-O-1 0111 (7) 8-E-1 1010 (A) 7-O-2 1111 (F) 8-E-2 BR4 High byte B7 B6~B4 B3 B2 B1 B0 Explanation RS-485 User Define 0: Disable 1:
Enable Reserved RS-232 User Define 0: Disable 1: Enable COM2 RS-485 setting 0: Serial Master Ethernet Server 1: Serial Slave Ethernet Client COM1 RS-232 setting 0: Delta Configuration 1: Modbus Mode 0: ASCII 1: RTU Content 00000000 (0) Disable Disable Serial Master Delta configuration ASCII 00000001 (1) Disable Disable Serial Master Delta configuration RTU