P014 Design Speed Specifies the design speed for the conveyor belt. Speed unit s are: metre/s if P005 = 1 or 2 feet/min. if P005 = 3, 4 or 5 P015 Speed Constant This value multiplied with the speed sensor frequency, calculates the actual belt speed. Entry: If speed input is wired for constant speed (TB1 5/6 jumpered), value defaults to 100. Enter the speed constant = from the supplied design data sheet or = speed sensor pulses per revolution* pulley circumference (m or ft)/ revolution * refer to speed sensor nameplate or consult Siemens Milltronics or their agent. Note: Common speed sensor pulses per revolution:
RBSS - 150.4 pulses/meter (45.8 pulses/ft.) TASS - 9.947 pulses/meter (3.03 pulses/ft.) Parameters P016 Belt Length The length of the conveyor belt (one belt revolution). Length units are: metre if P005 = 1 or 2 feet if P005 = 3, 4 or 5 Enter the belt length P017 Test Load The load to be referenced when performing a span. Load units are: kg/m if P005 = 1 or 2 lb./ft. if P005 = 3, 4 or 5 The value for P017 can be calculated as follows: Test Load=Total weight of of all test weights (kg) or (lb) idler spacing (m) (ft) End of Quick Start parameters. A calibration can now be performed. 7ML19985DJ01 Milltronics BW100 - INSTRUCTION MANUAL Page 51