FIXING hp Color 9850mfp 9.6 Replacing the fixing roller L, ball bearing L and the heat insulating sleeve L A. Periodically replaced parts/cycle • Fixing roller L: Every 100,000 copies • • Heat insulating sleeve L: Every 600,000 copies Ball bearing L: Every 600,000 copies B. Procedure 1. Remove the fixing unit. 2. Remove the fixing cover R. 3. Remove the fixing lower heater lamp. 4. Remove 2 screws [1] and then remove the fixing entrance plate L [2]. [2] Note: • Be careful not to damage the paper passage III DIS./ASSEMBLY • Be careful not to damage the surface of the section of the entrance plate L. fixing rollers U and L with the entrance plate L. [1] 5.
After loosening the stopper screw [1] once, [3] [2] open the fixing paper exit guide [2] up to the turnout position and retighten it temporarily and then remove the fixing roller L [3]. Note: • Be careful not to damage the surface of the fixing roller. [1] [1] 3-86