DeviceNet Slave Communication Module IFD9502 2.3 Address Setup Rotary Switch The two rotary switches SW1 and SW2 set up the node address on DeviceNet in decimal form. Setup range: 00 ~ 63 (64 ~ 99 are forbidden). 1. Example: If you need to set the node address of IFD9502 as 26, simply switch the corresponding rotary switch of X10 1 to “2” and the corresponding rotary switch of X10 0 to “6”. 2. Note: The changed values on SW1 or SW2 are only valid when IFD9502 is re-powered. When IFD9502 is operating, changing the set value of node address will be invalid.

2.4 Function Setup DIP Switch The DIP switch SW3 is to be used on the equipment connected to IFD9502, the selection of communication ports and setting up the baud SW3 DIP ON rate of IFD9502 and the master in DeviceNet. 1 2 3 4 5 6 7 8 1. Selecting equipment connected to IFD9502 z Example “On” and PIN 1 and PIN 2 to “Off” and re-power IFD9502. If the equipment connected to IFD9502 is Delta servo drive, you only need to switch PIN 3 in SW3 to z Note: The changed setting of DIP switch is only valid when IFD9502 is re-powered. When IFD9502 is operating, changing the setting of DIP switch will be invalid. 2.

Selecting IFD9502 communication mode DVP-PLC Application Manual 5 Address setting Description 0 ~ 63 Valid DeviceNet node address 64 ~ 99 Invalid DeviceNet node address PIN 3 PIN 2 PIN 1 Equipment Off Off On AC motor drive Off On Off Programmable logic controller Off On On Temperature controller On Off Off Servo drive On Off On Human machine interface On On Off Custom equipment On On On Configuration mode PIN 5 PIN 4 Communication mode Off Off RS-485 On On RS-232 Off On Incorrect setting On Off