Single-axis controllers General data and operating conditions 4 4.2 Tab. 4.2-1 If EMC conditions must be met, the permissible cable lengths can be reduced. Tab. 4.2-2 EMC limit value class for conducted noise emission in TN/TT systems: C2 to EN 61800-3 corresponds to class A to EN 55011 C1 to EN 61800-3 corresponds to class B to EN 55011 4.2-3 EDS94SPP101 EN 3.1-04/2007 Maximum motor and feedback cable lengths in [m] (for shielded motor cable with rated mains voltage) Type Device size with encoder without encoder E94AMxE0024 E94AMxE0034 E94AMxE0044 1 50 50 E94ASxE0024 E94ASxE0034 E94AMxE0074 ... E94AMxE0244 2 ... 3 100 100 E94ASxE0044 ... E94ASxE0244 E94ASxE0324 ... E94ASxE1044 6 ...
7 100 100 E94ASxE1454 ... E94ASxE3664 8S ... 9 150 150 E94ASxE4604 ... E94ASxE6954 10 150 150 Max.
shielded motor cable lengths for compliance with EMC protection requirement C1/C2 Type with RFI filter with mains filter without filter E94ASxE0024 E94ASxE0034 E94AZRS0044 -/50 m E94AZMS0034 25 m/50 m -/10 m E94ASxE0044 E94ASxE0074 E94AZRS0104 -/50 m E94AZMS0094 25 m/100 m -/10 m E94ASxE0134 E94ASxE0174 E94AZRS0294 -/50 m E94AZMS0184 25 m/100 m -/10 m E94ASxE0244 E94AZMS0314 25 m/100 m -/10 m E94ASxE0324 E94ASxE0474 E94ASxE0594 E94AZRS0544 50 m/100 m - -/50 m E94ASxE0864 E94ASxE1044 E94AZRS0954 50 m/100 m - -/50 m E94ASxE1454 - - -/150 m E94ASxE1724 E94ASxE2024 E94ASxE2454 E94ASxE2924 E94ASxE3664 E94ASxE4604 E94ASxE5724 E94ASxE6354 E94ASxE6954