A90 series Inverter User Guide 53 F05.13 Oscillation Suppression Gain 0 - 20000 100 ● F05.14 Oscillation Suppression End Frequency 0.00 - 600.00 Hz 55.00 ● F05.15 Sagging Control Frequency 0.00 - 10.00 Hz 0.00 ● F05.16 Energy Saving Rate 0.00 - 50.00 % 0.00 ● F05.17 Energy Saving Action Delay Time 1.00 - 60.00 s 5.00 ● F05.18 Compensation Gain of Magnetic Flux of Synchronous Motor 0.00 - 500.00 % 100.00 ● F05.19 Filter Time Constant of Magnetic Flux Compensation of Synchronous Motor 0.00 - 10.00 s 0.50 ● F05.20 VF Separate power supply for a given rate of change –50.00~50.00 % 0.00 ● F06 Vector Control Parameter Group This group of parameters users generally do not need to adjust, please refer to A90 user manual or visit www.sineedrive.com download function table electronic version.
F07 Protection Function Setting Group F07.00 Protection block selection E20 E22 E13 E06 E05 E04 E07 E08 000 00000 〇 0: Valid Protection 1: Protection blocked F07.01 Motor Overload Protection Gain 0.20~10.00 1.00 ● F07.02 Motor Overload Pre-Alarming Factor 50~100 % 80 ● F07.06 Bus voltage control selection Ones Place: continuious woking under instantaneous power failure 0: invalid 1: Deceleration 2: Deceleration and stop Tens Place: Overvoltage stall function 0: Disabled 1:
Enabled 10 〇 F07.07 Overvoltage Stall Control Voltage 110.0~150.0(380V,100.0=537V) % 131.0 (703V ) 〇 F07.08 Action threshold of continuious woking under instantaneous power failure 60.0~Recovery threshold voltage (100.0= Standard bus voltage) % 76.0 〇 F07.09 Recovery threshold of continuious woking under instantaneous power failure Action threshold voltage~100.0 % 86.0 ● F07.10 Recovery judgment delay time 0.00~100.00 s 0.50 ●