User Manual of A90 Series Inverter Output frequency Output frequency (Hz) Fbase (Hz) Fbase Time Time (s) t2 (s) (a) Acceleration time 1 (b) Deceleration time 1 t1 Fig. 7-4 Acceleration and Deceleration Time Note that the acceleration and deceleration time is in 0.01 s, 0.1 s or 1s, depending on the F15.13. The allowable maximum frequency of the inverter is represented by Fmax. The Fmax range is from 20.00 to 600.00Hz. F00.17=0: set by F00.18 The upper frequency limit is set by F00.18.

F00.17=1:AI1 126 Function code Default Function code Parameter description Unit Attribute name setting F00.16 Maximum frequency 1.00~600.00 Hz 50.00 ○ Function Default Function code name Parameter description Unit Attribute code setting F00.17 Options of upper frequency limit control 0: set by F00.18 1: AI1 2: AI2 3: retention 4: VP (keyboard potentiometer) 5: retention 6: percent setting of upper limit frequency communication 7: direct setting of upper limit frequency communication 0 ○ F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ●