sinee — Руководство по эксплуатации Inverter A90 от SINEE (EN)

User Manual of A90 Series Inverter 78 1: stop frequency 2: power frequency Tens place: Selection of search direction 0: search only in command direction 1: Search in the opposite direction if the speed cannot be found in the command direction F04.09 Reserved F04.10 Deceleration time of speed tracking 0.1~20.0 s 2.0 ○ F04.11 Speed tracking current 30.0-150.0 (100.0 = rated current of inverter) % 50.0 ○ F04.12 Speed tracking compensation gain 0.00~10.00 1.00 ○ F04.13 Reserved F04.14 Acceleration and deceleration mode 0: linear acceleration and deceleration 1: acceleration and deceleration of continuous S curve 2:

acceleration and deceleration of intermittent S curve 0 ○ F04.15 Starting time of S curve in acceleration 0.00 to system acceleration time/2 (F15.13 = 0) 0.0 to system acceleration time/2 (F15.13 = 1) 0 to system acceleration time/2 (F15.13 = 2) s 1.00 ● F04.16 Ending time of S curve in acceleration 0.00 to system acceleration time/2 (F15.13 = 0) 0.0 to system acceleration time/2 (F15.13 = 1) 0 to system acceleration time/2 (F15.13 = 2) s 1.00 ● F04.17 Starting time of S curve in deceleration 0.00 to system acceleration time/2 (F15.13 = 0) 0.0 to system acceleration time/2 (F15.13 = 1) 0 to system acceleration time/2 (F15.13 = 2) s 1.00 ● F04.18 Ending time of S curve in deceleration 0.00 to system acceleration time/2 (F15.13 = 0) s 1.00 ●