ABB ACS1600 Service manual Equipment: ABB ACS1600 drive Doc 3BSE 600001 Wall-mounted drive for textile machinery. Speed range 1 to 1000 Hz. Sensorless vector control. Coated electronics for humid halls. Follow all safety warnings before service.

Стр. 1

1. Specification Input 380-500 V three phase. Output current up to 450 A. Wall-mounted drive for textile machinery. Speed range 1 to 1000 Hz. Sensorless vector control. Coated electronics for humid halls. Enclosure IP54 as standard.

Стр. 2

2. Safety Warning: capacitors hold charge after power down. Wait five minutes, verify with meter. Only qualified service personnel allowed.

Стр. 3

3. Commissioning Set motor data plate values in parameter group 99. Run auto-tune both static and dynamic. Check direction of rotation at low speed first.

Стр. 4