omron — CalibratedUnitsEnabled

CalibratedUnitsEnabled CalibratedUnitsEnabled VPARAMETER 103 Returns 1 if the image the virtual camera image the tool is operating on has an active calibration applied. If no calibration is in effect, a 0 is returned. This property is read-only. Syntax MicroV+ value = VPARAMETER (sequence_id, tool_id, 103, index_id, object_id) V+ value = VPARAMETER ($ip, sequence_id, tool_id, 103, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 148 Value Description 1 Dimensions are expressed in millimeters. (Default) 0 Dimensions are expressed in pixel units. $ip IP address of the vision server. Applies to V+ syntax only.

Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 103: the value used to reference this property. index id _ N/A object id _ N/A