omron — RecognitionLevel

RecognitionLevel RecognitionLevel VPARAMETER 550 Configurable effort level of the search process. A value of 0 will lead to a faster search that may miss instances that are partly occluded. Conversely, a value of 10 is useful for finding partly occluded objects in cluttered or noisy images, or for models made up of small features at the Outline Level. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 550, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 550, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 550, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 550, index_id, object_id) Type Long Range Minimum: 0 Maximum:

10 Parameters ACE Reference Guide, 18317-000 Rev A Page 456 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 550: the value used to reference this property. index id _ N/A object id _ N/A