Reset Reset VPARAMETER 5500 Resets the data currently stored for the tool. This property is write-only. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 5500, index_id, object_id) = value V+ VPARAMETER (sequence_id, tool_id, 5500, index_id, object_id) $ip = value Type Long Range Not applicable Parameters ACE Reference Guide, 18317-000 Rev A Page 457 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5500: the value used to reference this property.
index id _ N/A object id _ N/A