Downloaded from https://www.everyspec.com ADS-65A-HDBK 4.8.3.11 Electrical Load Analysis Verify the Electrical Load Standard: An electrical load analysis should determine for each electrical system that adequate electrical sources are present for all system loading conditions under all operating conditions. Compliance: An electrical load and power source capacity analysis should be prepared in accordance with MIL-E-7016 . Reference: MIL-E-7016 . 4.8.3.12 Clearance Analysis Verify Clearance of the Sensor Standard: The integration of the sensor package should provide necessary ground, rotor, and weapons trajectory clearance to prevent any collision, or accidents. Compliance:

A clearance analysis should show that there is sufficient clearance between the sensor, ground, rotors, and the weapon’s trajectories. 4.8.3.13 Blast Overpressure Analysis Verify Weapon Effects on the Sensor System Standard: The launch effects from smoke, flames, and temperature deltas on the visual/infrared optics in the sensor system should also be characterized to determine any operational effects on the mission. Compliance: The analysis should describe the effects on the sensor systems/subsystems. 4.8.3.14 Electromagnetic Design and Analysis Verify Electromagnetic Design Standard: The sensor package should meet the requirements of ADS-37A-PRF for electromagnetic environmental effects.

Compliance: An analysis should be performed according to the requirements of ADS-37A-PRF for electromagnetic environmental effects to determine compliance. Reference: ADS-37A-PRF 16