Delta AH500 — 6.19.2 Explanation of Communication Instructions

AH500 Programming Manual The PLC receives the data. Additional remark: 1. Please refer to the additional remark on the instruction RS for more information about the related flags and the special registers. 2. The instructions FWD, REV, STOP, RDST, and RSTEF can be used several times in the program, but one instruction is executed at a time. 3. If the value in S exceeds the range, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2003.

6-410 Data Description ‘0’ 16#30 ADR 1 ‘1’ 16#31 ADR 0 ‘0’ 16#30 CMD 1 ‘6’ 16#36 CMD 0 ‘2’ 16#32 Data address ‘0’ 16#30 ‘0’ 16#30 ‘2’ 16#32 ‘0’ 16#30 Number of registers ‘0’ 16#30 ‘0’ 16#30 ‘2’ 16#32 ‘D’ 16#44 LRC CHK 1 ‘5’ 16#35 LRC CHK 0