Schneider Electric — Option Cards for Specific Applications

Altivar 16 AC Drive Display and adjustment of parameters, option cards for specific applications Fault codes: USF Undervoltage OLF Motor overload OSF Overvoltage drF Transient overcurrent, drive overheating ObF Overbraking InF Internal fault Description of the display/adjustment/local command option Similar to the VW3A16101 option, the VW3A16102 option allows local control (Start/Stop) and adds: - 2 keys: Start and Stop/Reset - 3 LEDs: Local, Forward (FW) and Reverse (RV) Switch located on the back allows selection of local control. To start the drive locally with the start push button, a direction command (FW/RV) and a reference signal must be present.

Description of the connection to PC option The VW3A16104 allows the drive to be connected to a personal computer via RS 232C. The software gives the following advantages: - Prepare a job in the design office without connecting the drive to the computer - Save configurations and adjustments on floppy or hard disk and download them into the drive - Provide a printout of documents for future reference The software allows access to all the adjustments of the VW3A16101 display options as well as the supplementary functions of the option card. It also allows the reassignment of the inputs and outputs of the option cards.

[1] Option cards for specific applications [1] By installing an option card, the Altivar 16 can be adapted to a particular application. Description For Drives Catalog Weight Numbers lbs (kg) VW3-A16201 General use/material handling card ATV16 all ranges VW3A16201 _[2] 0.44 (.20) Variable torque card ATV16 all ranges VW3A16202 _[2] 0.44 (.20) (pumps, fans) High speed motor card ATV16 all ranges VW3A16203 _[2] 0.44 (.20) (textile, wood industry) When first installed, the option card automatically configures the following:

- Output voltage, switching frequency and configuration of the voltage/frequency ratio - Functions specific to the application - Associated inputs and outputs Modification of the configuration and adjustment parameters, especially the specific functions, requires the addition of one of the display/adjustment options. Note : with the VW3A16102 option, the specific control functions take priority over local control. [1] See detailed description, pages 14 and 15, and 19-29. [2] This number indicates an option without a user's manual. Add a letter at the end of the part number to obtain a user's manual in the following languages:

U =English (United States), E = English (United Kingdom), F =French, G =German, S =Spanish. 11