Delta Electronics — 6.26.2 Explanation of High-speed Output Instructions

AS Series Programming Manual 4. There is no limit to how many times you can use the instruction a program. But only one output instruction that uses the same output point can be executed in the same scan cycle. When several high-speed pulse output instructions start the same output point in the program, the PLC first performs the output based on the instruction that is executed first. 5. If S 1 ≦ 0 or S 2 ≦ 0, it is processed as 0 (the pulse output is OFF). If S 1 > S 2, it is processed as S 1 = S 2. When S 1 = S 2 and S 2 is not 0, the pulse output is always ON. 6. You can modify the pulse output width S 1 and pulse output cycle S 2 when the PWM instruction is executed. 7.

The relevant special registers SR are listed in the following table. #1 : All present output positions are latched when power is off. _6 8. Refer to Example 3 from the DJOG instruction (API 2703) for programming in ST language. Example When X0.0 is ON, Y0.1 outputs the following pulses. When X0.0 switches to OFF, Y0.1 output changes to OFF.

t=1000ms T=2000ms 6-792 Output point number Attribute Y0.0 Y0.1 Y0.2 Y0.3 Y0.4 Y0.5 Present output position#1 (32-bit) R/W SR460 SR461 SR474 SR475 SR480 SR481 SR494 SR495 SR500 SR501 SR514 SR515 Output point number Attribute Y0.6 Y0.7 Y0.8 Y0.9 Y0.10 Y0.11 Present output position #1 (32-bit) R/W SR520 SR521 SR534 SR535 SR540 SR541 SR554 SR555 SR560 SR561 SR574 SR575 Output Y0.1 Output Y1