Delta Electronics — 6.26.2 Explanation of High-speed Output Instructions

AS Series Programming Manual Some flags, such as S curve ramp-up/down, fixed slope ramp-up/down, and executing an interrupt program when pulse output ends, are not supported by the odd output points. If the output is ongoing, the preset output is the ramp-down stop when the instruction is disabled or stops temporarily. If the output must be stopped immediately, set the immediately stop flag to ON. 7. For PLC with FW V1.06.00 or later, added new SR652, SR653 for displaying number of pulse in ramp-up area and new SR654, SR655 for displaying number of pulse in ramp-down area. Refer to the following table for Attribute, Factory default and latched values of SM/SR corresponding to the axes.

_6 6-812 Start/end SR476 SR496 SR516 SR536 SR556 SR576 frequency(Hz) Ramp-up/down time SR477 SR497 SR517 SR537 SR557 SR577 (ms) Item Attribute StopRun RunStop Power ON Factory default Latched Busy flag R OFF OFF OFF OFF N Completion flag R / W OFF OFF OFF OFF N Stop flag R / W OFF OFF OFF OFF N Output completion R / W OFF OFF OFF OFF N auto-reset Enabling S curve R / W OFF OFF OFF OFF N ramp-up/down Enabling fixed slope R / W OFF OFF OFF OFF N ramp-up/down Executing an interrupt R / W OFF OFF OFF OFF N program when pulse output ends The output R / W OFF OFF OFF OFF N immediately stops when the instruction is disabled or stops Present output R / Wd No change No change No change 0 Y position Start/end R / Wd No change No change No change 200 Y frequency(Hz)