Delta Electronics — 6.26.2 Explanation of High-speed Output Instructions

AS Series Programming Manual 6. Software limit function a) The following diagram shows the output curve diagram of axis 1 (Y0.0/Y0.1). b) Operation of the positive limit  Positive software limit position is set in HWCONFIG (by setting SR580=11,000 for example). After downloading the setting to the PLC, it means the positive limit function starts. positive direction if the positive limit is exceeded when the function starts.  DDRVI starts to output 20,000 pulses in the positive direction. Note: the instruction does not output in the _6  When the current position SR460 > the limit position SR580, it means that the condition for the software limit function is met.

 DDRVI instruction stops the output immediately and the positive limit alarm SM465 is ON.  If the condition for the limit function is not met, Y0.0 stops the output after 20,000 pulses. 6-818 Positive limit function Negative limit function