Delta Electronics — 6.17.2 Explanation of Real-time Clock Instructions

AS Series Programming Manual Mode 1 (S=1): enabled by month and date (refer to example 2) Note 1: If this function is enabled, the value in D is ON. Note 2: If the date is set incorrectly, the daylight saving function cannot be enabled. The SM0 is ON, and the error code in SR0 is 16#200B. For example if a non-existed date is set, such as April 31, or the starting date is set smaller than the ending date in a calendar year, for example starting date is October 1 and ending date is April 01. Note 3: If S 5 is set out of range, the daylight saving function cannot be enabled. The SM0 is ON, and the error _6 code in SR0 is 16#200B. Mode 2 (S=3):

enabled by week and weekday (refer to example 3) 6-510 Operand Description S1 The month to start daylight saving time Range: 1-12 S2 The date to start daylight saving time Range: 1-31 S3 The month to end daylight saving time Range: 1-12 S4 The date to end daylight saving time Range: 1-31 S5 Time that changed due to daylight saving time; unit: minute Range: 1-1439 (within 1 day) Operand Description S1 The month to start daylight saving time Range: 1-12 S2 S2+1 S2: settings for the week to start daylight saving time; range: 1-4 S2+1: on which weekday of the S2; range: 1-7 (Monday: 1, Tuesday: 2…, Sunday: 7) S3 The month to end daylight saving time Range: 1-12 S4 S4+1 S4:

settings for the week to end daylight saving time; range: 1-4 S4+1: on which weekday of the S4; range: 1-7 (Monday: 1, Tuesday: 2…, Sunday: 7) S5 Time that changed due to daylight saving time; unit: minute Range: 1-1439 (within 1 day)