Chapter 6 Applied Instructions t=1000ms Y0.0 T=2000ms Additional remarks 1. The instruction counts by the scan cycle. Therefore, the maximum error is one scan cycle. Besides, S 1 , S 2 , and ( S 2 - S 1 ) should be larger than the scan cycle; otherwise, an error occurs when the GPWM instruction is executed. 6_ 2. If you use the instruction in a function block or an interrupt task, an inaccurate pulse output occurs. 3. If you declare the operand S 2 in ISPSoft, the data type is ARRAY [3] of WORD/INT. 6-635