Delta Electronics — 6.22.2 Explanation of Ethernet Instructions

AS Series Programming Manual Symbol Index, Mail : Refer to following explanation Explanation 1. This instruciton is available for PLC with FW V1.06.00. 2. See the operand name, use explanation and data type in the following table. 6-744 API Instruction Operand Description 2212 EMCONF2 P Index,Mail Setting email address Device X Y M S T C HC D FR SM SR E K 16# “$” F Index     Mail    BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type Refer to following instruction explanation Pulse Instruction 16-bit instruction 32-bit instruction AS AS - 6 _ Operand Name Explanation Data type Remark Index Mail address number Index:

The mail address number to be modified (Range: 0~4, 0: Not modify the mail address.) WORD Mail Mail address Mail +0: the data length of Index value with the unit of bytes (range: 0~63, 0: Not modify the mail address.) Mail +1~ Mail +32: The data content of Index (Data are placed from the lower 8 bits.) For example: ex@deltaww.com D0 = 16#000E, D1 = 16#7865, D2 = 16#6440, D3 = 16#6C65, D4 = 16#6174, D5 = 16#7777, D6 = 16#2E63, D7 = 16#6D6F WORD[N] Refer to Mail +0 for address occupation. 33 consecutive words at most can be occupied. Up to 63 words can be used in one string String