Delta Electronics — 2.3 Mounting direction and space

ASDA-B3 Installation Heat dissipation requirements  To lower the wind resistance of the fan for better heat dissipation, follow these diagrams for the suggested clearance values when installing one or more servo drives. 2  Avoid mounting one servo drive above one another. Keep the bottom of the servo drive clear because the generated heat rises and causes higher temperature for the drives mounted above. One servo drive Multiple servo drives Note: the diagrams are not accurately scaled. Refer to the annotations on the diagrams. Cabinet 2-5 min. 25 mm (1inch) min. 50 mm (2 inch) min. 25 mm (1 inch) min. 50 mm (2 inch) Air Flow Air Flow min. min. min.

50 mm 25 mm 25 mm (2 inch) (1 inch) (1 inch) Air Flow Air Flow min. 100 mm (4 inch) min. 50 mm (2 inch) min. 80 mm (3.2 inch)