Delta Electronics — 3.1.7 IP67 connector wiring instructions

Wiring ASDA-B3 3.1.7 IP67 connector wiring instructions Follow these wiring instructions: 3 8 - 12 mm Step 1: Cut through the cable and expose the shielding. 2 - 3 mm The exposed wire length should be 8 - 12 mm (0.31 - 0.47 inches) and the tinned wire length should be 2 - 3 mm (0.08 - 0.12 inches). Step 2: Place the (A) seals nut, (B) seals ring, (D) (C) (B) (A) (C) clamp ring, and (D) gasket on the cable in sequence. Note: place the flat face of the gasket outwards and the groove face towards the clamp ring for the IP67 design. Step 3: (1) For the power connector, refer to Section 3.1.4 for the pin assignment to connect the pins.

(2) For the encoder connector, refer to Section 3.1.5 for the pin assignment to connect the pins. (B) Step 4: Place the groove face of the (A) gasket towards (A) the clamp ring and fit it into the (B) clamp ring. Step 5: Use a wrench to lock the clamp ring to the housing and place the seals ring in the clamp ring. Step 6: Use a wrench to lock the seals nut to the clamp ring to complete the wiring. 3-30