omron — Controlling a Process

Controlling a Process Controlling a Process For some applications, it may be necessary to stop certain processes (for example, stopping an upstream robot and allowing a downstream robot to clear the belt of all remaining product) before stopping the entire application. The OPC Data Access and Process Control feature can be used to control (remotely start or stop) a specified ACE process. To enable this feature: 1. Install and enable the OPC Data Access and Process Control feature. For details, see Installing and Enabling OPC on page 785. 2. For the OPC options, select Export, and verify that Read-only is not selected. Selecting the Process to Control NOTE:

The Process Index value represents a process on the Process Manager editor Processes list. Because ACE, like V+, uses a zero-based index, the first process on the list would be '0', the second would be '1', and so on. 3. In your OPC client application, create an OPC tool that writes to the exported value. This will be used to start/stop the specified process. See your OPC client documentation for details. ACE User's Guide, 3.6.x, 18316-000 Rev A Page 793