TPD1317e Chapter 3 Bracket with link to allow for movement due to expansion in the exhaust system (horizontal exhaust systems should be suspended from the deck head using similar brackets - rigid brackets should not be used). Insulating lagging Rigid bracket to support the weight of the vertical exhaust system Heat blanket Twin stainless steel belows fitted to avoid torsional load on bellows unit Flanges shown without bolts for clarity 90 O Elbow Heat blanket Figure 5 - Dry Exhaust System Features - M185C, M215C, M225Ti, M265Ti & M300Ti Note:
When fitted, the bellows units should be in an unstrained condition so that the full bellows movement is available to absorb expansion and engine movement. Page 15