AT Commands User Manual − 1: indicator event reporting using result code +CIEV: , . indicates the indicator order number (as specified for +CIND) and is the new value indicator. Only the indicator events which are not caused by +CIND shall be indicated by the TA to the TE. − 2: indicator event reporting using result code +CIEV: , . All indicator events shall be directed from TA to TE. may have the following values: − 0: TA buffer of unsolicited result codes defined within this command is cleared when 1...3 is entered − 1: TA buffer of unsolicited result codes defined within this command is flushed to the TE when 1...3 is entered (OK response shall be given before flushing the codes). :

string type value; format is “yy/MM/dd,hh:mm:ss+TZ”, wherein characters indicates year, month, day, hour, minutes, seconds. TZ: Time zone information represented by two digits. The time zone information is optional; if it was entered it is always accepted, but the display of TZ for query contains this information (in updated form) only if the network supports the time zone information. : string type value; format is “yy/MM/dd,hh:mm:ss+tz”, wherein characters indicates year, month, day, hour, minutes, seconds and time zone. Note: if the parameter is used, the parameter must not contain a date. , , :

integer type value indicating the index of the alarm; the maximum number of alarms is 3; if not indicated by user, default value 1 is assumed 15 5.9 Clock +CCLK Command syntax Description AT+CCLK= AT+CCLK=”02/07/01,14:54:00” This set command sets the real-time clock of the ME. OK or CME ERROR: Read command AT+CCLK? +CCLK: “02/07/01,14:55:00” OK Test command OK AT+CCLK=? 5.10 Alarm +CALA Command syntax Description AT+CALA= , , , , , AT+CALA=”02/07/ 01,14:56:00+04”,1,1,”Alarm” This set command sets an alarm time in the MT. At expiration a predefined text is displayed. There can be an array of different types of alarms, and each alarm may cause different text to be displayed in the MT display.

If setting fails, a CME ERROR: is returned. To set up a recurrent alarm for more days in the week, the parameter is used. When an alarm is timed out and executed, first the alarm actions are executed as display of provided text and e.g sound alarm, and second, the unsolicited alarm code +CALV: is displayed on DTE, even if the alarm was silent. OK or CME ERROR: Read command AT+CALA? +CALA: , , , , , +CALA: , , , , , [...] i.e. +CALA: ”02/07/01,14:56:00+04”,1,1,”Alarm”,0 OK Test command AT+CALA=? +CALA: (list of supported s),(list of supported s), , ,(list of supported ’s) OK