Sauer-Danfoss — BAIC Hydrostatic Drive System Service Manual PDF (EN)

DRIVE MOTOR 2.11 Disassembly (cont’d) Disk Valve Guide Pins(3) Springs(5) Bolts(9) 2 Balance Plate Spacer Shuttle Housing 5 Use a 6mm Allen key to remove the flushing valve plug. (fig. C3510) C3509 Shuttle valve plug C3510 6 Below the plug, the spring guide and the spring are easily removed. (fig. C3511) Spring Plug Spring Guide C3511 Flushing Spool 7 The flushing spool is deep within the housing and is very difficult to remove with a magnet. A pair of long thin pliers works much better. (fig. C3512) C3512 2-35