Sauer-Danfoss — BAIC Hydrostatic Drive System Service Manual PDF (EN)

DRIVE MOTOR 2.11 8 Carefully remove spool from the housing to avoid scoring. (fig. C3513) Disassembly (cont’d) Spool 2 9 Remember that the spool is set at an angel within the housing. (fig. C3514) C3513 Spool C3514 10 The second spring is deep within the housing. It is not necessary to remove this spring unless it is suspected of failure. (fig. C3515) 11 The complete flushing valve assembly. Carefully examine prior to reinstalling into housing. (fig. C3516) Second Spring C3515 Flushing Valve Assembly C3516 2-36