219 WEBM1000 Maintenance and Lubrication Section (Pipelayer Attachment Kit) 292 Hook and Wire Cable – Inspect Inspect the Hook Inspect the hook frequently. The inspections should include observation of the hook during operation of the hook. A designated person determines if the conditions that are found during the inspections constitute a hazard. The designated person will determine if a more detailed inspection is required. Inspect the hook for any distortion such as bends in the hook or twists in the hook. Inspect the hook for any wear. Inspect the hook for cracks, nicks, or gouges. Illustration 292 Counterweight hinge pins lubrication points If a latch is provided, inspect the latch.
Make sure that the latch engages properly. Inspect the latch for any damage. Make sure that the latch is not malfunctioning. Fairlead Sheave – Lubricate 293 Inspect the hook assembly and the means for securing the hook assembly. For additional information on the proper maintenance and on the proper inspection of hooks, refer to "American National Standard Institute ANSI/ASME B30.14". Inspect Wire Cable - Boom and Hook lines Make a visual inspection of all running cables that are in continuous use. Make the inspection of the running cables on a daily basis before the machine is placed in operation. Inspect all of the cables on a monthly basis.
All inspections shall be performed by a designated person. Keep a dated report of the condition of the cable on file in a location that is available to designated personnel. Perform a close inspection of the sections of the cable that are normally hidden during the visual inspection and the maintenance inspection. (This includes the sections of the cable that pass over the sheaves.) These points are the sections of the cable that are most likely to fail. Illustration 293 Fairlead sheave lubrication points Lubricate one fitting in the lower sheave and lubricate one fitting in the upper pin. Note any deterioration that results in a notable loss of the original strength.
(See the conditions that are described below.) Determine if further use of the cable will constitute a hazard. Inspect the cable on a daily basis for the following conditions: