Caterpillar — Inspect Wire Cable - Boom and Hook lines

220 Maintenance and Lubrication Section (Pipelayer Attachment Kit) WEBM1000 Hook Load Line – Install Inspect the cable for a reduction in the diameter of the cable below the nominal diameter. A loss of support in the cored wire of the cable may be caused by internal corrosion, external corrosion, or wear of the outside wires. Note: For additional information on the proper maintenance and on inspection of the cable, refer to "American National Standards Institute ANSI/ASME B30.14". Inspect the cable for broken outside wires. Check for the degree of distribution of the broken outside wires. Check for the concentration of outside broken wires.

Hook Load Line – Install m WARNING Inspect the cable for worn outside wires. Do not operate or work on this equipment unless you have read and understand the instructions and warnings in the Operation and maintenance Manual. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility. Inspect the cable for corroded wires and for broken wires at the connection on the wire cable end. Inspect the cable end for connections that are corroded, cracked, bent, worn, or improperly installed. m WARNING Personal injury or death can result from worn wire rope cable. Worn or frayed cable could break causing injury. Check the wire rope cable.

If cable is worn or is frayed install new cable. Wear gloves when handling the wire rope cable. Inspect the cable for sections that are crushed or kinked and for any loose wire strands. Excessive wear or broken wires may occur in sections of the cable that are in contact with saddles, equalizer sheaves, or other sheaves. Excessive wear or broken wires can also occur when cable travel is limited. Take care to inspect the ropes at these locations. NOTICE Make sure that the construction of the wire rope is 6x25 IWRC XIPS (Independent Wire Rope Core, eXtra Improved Plow Steel) USA MADE.

Also, the established grade of the wire rope is the improved plow bolt (steel), 26670 kg (58 800 lb) minimum breaking strength. When a machine is shutdown for a month or more, inspect all of the cables thoroughly. When a side boom machine has been in storage for a month or more inspect all of the cables thoroughly. The inspection should be completed before the machine is returned to operation. Table 35 Hook Load Line Cable Boom Length Diameter Length 6.1 m (20 ft) 19.05 mm (0.75 inch) SPECIFICATIONS (WIRE ROPE) The inspection should be for all types of deterioration. The inspection should be performed by a designated person or by an authorized person.

The authorized person's approval is required for further use of the cable. 50.3 m (165 ft) 7.3 m (24 ft) 19.05 mm (0.75 inch) 57.3 m (188 ft) A dated report on the condition of the cable should be kept on file. 1. Lower the boom to the horizontal position. 2. Remove the anchor for the wire rope from the drum for the hook. Remove the old wire rope. Take care in the inspection of cable that is resistant to rotation. Any new poured socket or swaged socket assembly that is used as a standing cable (guy) shall be proof tested. Test the cable to the lift capacity of the side boom machine or to the manufacturer's recommendation. 3. Unroll the new wire rope from the spool. Note:

Weld the cable ends in order to prevent fraying. NOTICE Unroll all of the cable from the spool. Lay the wire rope on a flat surface. Never lift the wire rope off the spool in coils. Never give the cable a rating that is greater than 50 percent of the wire rope's nominal strength or of the structural strand's nominal strength.