Detroit Diesel — Detroit Diesel MBE 4000 Service Manual (EN)

EPA07 MBE 4000 SERVICE MANUAL 2.12 FUEL HAND PRIMER PUMP The following sections support the fuel primer. 2.12.1 Removal of Fuel Hand Primer Pump Removal steps are as follows: 1. Bolts (Primer Mounting) 4. Fuel Hand Primer Pump 2. Mounting Bracket 5. Additional Priming Port 3. Bolts (Bracket Mounting) 6. Fuel Outlet Line Figure 2-35 Fuel Hand Primer Pump 1. Remove the banjo bolt and washers attaching fuel outlet line to bottom of fuel primer. Discard the washers. See Figure 2-35. 2. Remove the fuel inlet connection to the fuel primer. 3. Remove two bolts securing the fuel primer to the mounting bracket and remove the primer. See Figure 2-35. 4.

If necessary, remove the fuel primer mounting bracket by removing three bolts securing the primer to the air mixer housing. See Figure 2-35. 2.12.2 Installation of Fuel Hand Primer Pump Installation steps are as follows: All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-55