Detroit Diesel — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\compdisp049\compdisp

EPA07 MBE 4000 SERVICE MANUAL 2.12 FUEL HAND PRIMER PUMP The following sections support the fuel primer. 2.12.1 Removal of Fuel Hand Primer Pump Removal steps are as follows: 1. Bolts (Primer Mounting) 4. Fuel Hand Primer Pump 2. Mounting Bracket 5. Additional Priming Port 3. Bolts (Bracket Mounting) 6. Fuel Outlet Line Figure 2-35 Fuel Hand Primer Pump 1. Remove the banjo bolt and washers attaching fuel outlet line to bottom of fuel primer. Discard the washers. See Figure 2-35. 2. Remove the fuel inlet connection to the fuel primer. 3. Remove two bolts securing the fuel primer to the mounting bracket and remove the primer. See Figure 2-35. 4.

If necessary, remove the fuel primer mounting bracket by removing three bolts securing the primer to the air mixer housing. See Figure 2-35. 2.12.2 Installation of Fuel Hand Primer Pump Installation steps are as follows: All information subject to change without notice. DDC-SVC-MAN-0026 Copyright © 2011 DETROIT DIESEL CORPORATION 2-55