TESTING AND ADJUSTING EMERGENT ESCAPE FROM FAILURE IN ENGINE CONTROL SYSTEM EMERGENT ESCAPE FROM FAILURE IN ENGINE CONTROL SYSTEM If a failure occurs on any of the engine control de- vices like fuel dial, governor pump controller or governor motor potentiometer, and the engine gets out of control, first fix the engine rpm and take the following steps to avoid the immediate danger. The suggested steps are provisional ones. Iden- tify the cause for the failure and carry out repairs promptly thereafter. 3. Remove bolt (4), connect governor spring (3) and fix it at the original position. Tilt the governor motor lever to the fuel injec- tion pump side, but stop short of the gover- nor spring.
The governor lever of the fuel injection pump is fixed at a near-idling position. 1. Disconnect E11 connector (1) of the governor motor from E10 connector (2) of the governor potentiometer. k If the governor motor connector is left con- nected, the governor motor will be suddenly activated while the engine is running, caus- ing a mechanical damage. Be sure to dis- connect it. 4. Start the engine again and travel the machine to a safe place. 5. Disconnect governor spring (3) and stop the engine. k Operation of stopping the engine is to be carried out while the engine is running at high speed. Be careful not to touch the parts of high temperature or get caught in rotating parts.
If the governor spring is tilted all the way to the fuel injection pump, the pump stops with no more injection. Hold the governor spring until the engine comes to a complete stop. Otherwise the fuel injection pump automatically returns to the low idling position, and the engine does not stop. 2. Detach governor spring (3) on the governor motor side. PC210/240-7K 20-113