Komatsu — MEASUREMENT OF CLEARANCE IN SWING CIRCLE BEARINGS

TESTING AND ADJUSTING MEASUREMENT OF CLEARANCE IN SWING CIRCLE BEARINGS MEASUREMENT OF CLEARANCE IN SWING CIRCLE BEARINGS Swing circle bearing clearance measurement tools 4. Hold the arm nearly perpendicular to the ground, and lower the boom until the track shoes will be lifted at the machine front. The upper structure is raised at the front and lowered at the rear at that time. Follow the steps explained below, when measur- ing clearance in the swing circle bearing in the actual machine. 5. Read off the value in dial gauge H in this condi- tion. The value indicated in dial gauge H express- es clearance in the bearings.

k Be careful not to put a hand or foot under the un- dercarriage, while taking measurement. 1. Fasten dial gauge H to swing circle outer race (1) or inner race (2), and contact the probe with the end surface of inner race (2) or outer race (1) on the opposite side. Set dial gauge H at the machine front or rear. 6. Return the machine to the posture in Item 2 above, and confirm reading of dial gauge H is zero. If zero value is not indicated, repeat the steps in Items 3 through 5. 2. Keep the work equipment in the max. reach pos- ture and keep the height of the bucket teeth tip level with the lower height of the revolving frame.

The upper structure is lowered at the front and raised at the rear at that time. 3. Set dial gauge H at zero point. 20-114 PC210/240-7K Mark Part No. Part Name H Commercial Product Dial Gauge