Komatsu — MEASUREMENT OF SOLENOID VALVE OUTPUT PRESSURE

TESTING AND ADJUSTING MEASUREMENT OF SOLENOID VALVE OUTPUT PRESSURE 5. Run the engine at full throttle, then turn each solenoid valve ON or OFF by operating the con- trol lever switch, and measure the pressure. For conditions for turning each solenoid valve ON or OFF, refer to the ensuing "Table for Functioning Conditions" for each sole- noid valve. How each solenoid valve functions can be confirmed with monitoring function in the monitor panel. (Special Function of Machine Monitor) When each output pressure shows the fol- lowing values, it is judged normal. 6. Detach all the measurement tools after the mea- surement, and make sure that the machine is back to normal condition.

Table for Functioning Conditions - Swing and parking brake solenoid Table for Functioning Conditions - PPC lock solenoid valve Table for Functioning Conditions - Travel interconnection solenoid valve Table for Functioning Conditions - Travel speed shifting solenoid valve : The "Mi" mode is on the multi-monitor specification machine only.

20-136 PC210/240-7K Solenoid Valve Output Pressure OFF (Demagnetization) 0{0} ON (Excitation) 3MPa{30kg/cm2} Functioning Condition Functioning Work equipment, swing, travel, signaling When all of them is OFF OFF When any of them is ON ON Functioning Condition Functioning Safety lock lever Locked OFF Released ON Functioning Condition Functioning When the travel steering signal is ON ON When the travel steering signal is OFF Traveling operation only If front or rear pump pressure is over 24.5MPa{250kg/cm2} ON In conditions other than above OFF Functioning Condition Functioning When overheat setting of the 2nd stage is ON OFF When the fuel dial indicates less than 1500 rpm When the travel speed switch is at Lo (or Mi) When the travel speed switch is at Hi The travel signal is OFF The travel signal is ON If front or rear pump pressure is 24.5 MPa{250 kg/cm2} If front or rear pump pressure is 15.3 MPa{150 kg/cm2} ON In conditions other than above