Komatsu — Table for Monitoring Items

TESTING AND ADJUSTING SPECIAL FUNCTION OF MULTI-MONITOR PANEL 4) Function for Pump Absorption Torque adjustment The pump absorption torque can be adjusted within the range shown in the table below. 5) Function for Low Idle Speed adjustment The engine rotation at low idling can be adjusted within the range shown in the table below. 6) Function for Service Current Adjust. When a machine is used for a compound operation, distribution of hydraulic pump oil flow can be adjusted within the range shown in the table below.

20-170 PC210/240-7K Adjustment value Torque adjustment value 220 +4.0 kgm 221 +3.0 kgm 222 +2.0 kgm 223 +1.0 kgm 224 0.0 kgm 225 –1.0 kgm 226 –2.0 kgm 227 –3.0 kgm 228 –4.0 kgm Adjustment value Low idling rotation 320 1,000 rpm 321 1,100 rpm 322 1,200 rpm 323 1,300 rpm Adjustment value Distribution of oil flow to attachment 320 0.5 Time 321 0.7 Time 322 1.0 Time 323 0.4 Time