Komatsu — Service Code in Electrical System (Disconnection in LS-EPC solenoid system)

TESTING AND ADJUSTING E223 Service Code in Electrical System (Disconnection in LS-EPC solenoid system) E223 Electrical Circuit Diagram for LS-EPC Solenoid in Governor • Pump Controller PC210/240-7K 20-345 User Code Se rvice Code Failure Code DXE0KA p Failure henomenon Disconnection in LS-EPC solenoid (in governor • pump controller system) — E223 Failure content • N o current flows to the LS-EPC solenoid circuit. Response from • N controller • W one in particular (The solenoid does not function as there is no current flowing to it) hen the failure cause disappears of itself, the machine operation returns to normalcy.

Phenomenon • T occurring on • In machine he travel speed is slow at Mi and Lo. L mode, speeds of the work equipment and swing are too fast. Relative • O information (C utput to LS-EPC solenoid (ampere) can be confirmed in the monitor function. ode No. 015: LS-EPC solenoid current) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 ★ LS-EPC solenoid defec- tive (Internal short-circuiting) Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

V22 (male) Resistance value Between and 7 – 14 Ω 2 ★ Disconnection of wiring harness B (Disconnection or defec- V tive contact with connec- tor) W (f Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. etween wiring harness between C03 (female) and 22 (female) and grounding Resistance value Below 1 Ω iring harness between C03 (female) and V22 emale) Resistance value Below 1 Ω 3 ★ Short-circuiting of wiring harness (Contact with 24 V cir- B cuit) V Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.

etween wiring harness between C03 (female) and 22 (female) and grounding Voltage Below 1 V 4 ★ Governor • pump controller defective Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and 7 – 14 Ω