Komatsu — Service Code in Electrical System (Abnormality in F pump pressure sensor)

TESTING AND ADJUSTING E224 Service Code in Electrical System (Abnormality in F pump pressure sensor) E224 20-346 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormality in F pump pressure sensor (in governor • pump controller system) — E224 DHPAMA Failure content • Signal voltage from the F pump pressure sensor dropped below 0.3 V or exceeded 4.72 V. Response from controller • The controller controls the F pump pressure at 0 MPa{0 kg/cm2}. • If the failure cause disappears, the sensor returns to normalcy of itself. Phenomenon occurring on machine • The travel speed does not shift automatically.

Relative information • Input from the F pump pressure sensor (pressure) can be confirmed in the monitor function. (Code No. 011: F pump pressure) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Sensor power source fault If the Service Code No. [E226] is displayed, troubleshoot the failure first. 2 F pump pressure sensor defective (Internal failure) ★Turn the engine starting switch OFF for the preparations, and keep the engine running during the troubleshooting.

A51 Voltage Between and 4.5 – 5.5 V Between and 0.5 – 4.5 V 3 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness from C01 (female) to J07 to A51 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and A51 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and A51 (female) Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between C01 (female) and A51 (female) and grounding Resistance value Above 1 MΩ 5 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. Between wiring harness between C01 (female) , J07 and A51 (female) and grounding Voltage Below 1 V Between wiring harness between C01 (female) and A51 (female) ang grounding Voltage Below 1 V 6 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and keep the engine running during the troubleshooting. C01 Voltage Between and 4.5 – 5.5 V Between and 0.5 – 4.5 V