TESTING AND ADJUSTING E228 Service Code in Electrical System (Short-circuiting in attachment return switching relay) E228 Electrical Circuit Diagram for Attachment Return Switching Relay and Solenoid PC210/240-7K 20-353 User Co de Service Code Failure Code D196KB Failure phenomenon Short-circuiting in attachment return switching relay (in governor • pump controller system) — E228 Failure co ntent • Abnormal current flew to the attachment return switching relay circuit , when it was grounded (power ON). Response controller from • The controller turned OFF power to the attachment return switching relay circuit.
• Even when the failure cause disappears of itself, the current does not return to normalcy. Phenomen occurring machine on on • The hydraulic circuit for attachments is not switched to the single operation circuit. Relative informatio • It can be confirmed in the monitor function how the attachment return switching relay circuit works (ON n or OFF). (Code No. 024:Solenoid 2) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting Atta 1 swi (Int chment return tching relay defective ernal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
R20 (male) Resistance value Between and 100 – 500 Ω Sho har 2 (Co cuit rt-circuiting of wiring ness ntact with 24 V cir- ) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. Between wiring harness between C02 (female) and R20 (female) and grounding Voltage Below 1 V Go 3 con vernor • pump troller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. C03 Working mode Voltage Between and grounding Other than B mode 20 – 30 V B mode Below 1 V