TESTING AND ADJUSTING E232 Service Code in Electrical System (Short-circuiting in PC-EPC Solenoid E232 20-354 PC210/240-7K User Code Service Code Failure Code DXA0KB Failure phenomenon Disconnection in PC-EPC solenoid (in governor • pump controller system) E02 E232 Failure content • Abnormal current flew to the PC-EPC solenoid circuit. Response from controller • The controller reduces the output to the PC-EPC solenoid circuit to 0. • Even if the failure cause disappears, the current does not return to normalcy, unless the engine starting switch is once turned OFF.
Phenomenon occurring on machine • As load to the pump increases, the engine rotation drops sharply and sometimes the engine stalls. Relative information • Output to PC-EPC solenoid (ampere) can be confirmed in the monitor function. (Code No. 013: PC-EPC solenoid current) • If there is no abnormality with the solenoid or any of the wiring harnesses, the machine can be operated in a working mode equivalent to E mode by turning the emergency drive switch ON. (At that time the monitor panel continues to display service code No. [E232], but this is not abnormal) ★Turn the emergency driving switch ON during the troubleshooting.
Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 PC-EPC solenoid defec- tive (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. V21 (male) Resistance value Between and 7 – 14 Ω Between and grounding Above 1 MΩ 2 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C03 (female) to S21 to V21 (female) and grounding Resistance value Above 1 MΩ 3 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and 7 – 14 Ω Between and grounding Above 1 MΩ