Komatsu — Failure Code in Mechanical System A000N2 (Out-of-rate engine rotation at low idling)

TESTING AND ADJUSTING E501 / E502 Service Mode in Electrical System (Model selecting signal fault) E502 PC210/240-7K 20-377 User Code Service Code Failure Code Failure phenomenon Model selecting signal fault (in governor • pump controller system) — E502 DA20KT Failure content • Information on the models stored in the controller have been damaged. Response from controller • Model data and rated load cannot be set. • Even when the failure cause disappears, the signal does not return to normal, unless the engine starting switch is once turned OFF. Phenomenon occurring on machine • The excess load alarm does not work normally.

Relative information • (Model names that the controller recognizes (figure) can be confirmed in the monitor function. (Code No. 150: Model Code) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Setting work not finished yet Refer to the section "Special Function of Monitor Panel" in this manual. 2 Governor • pump controller defective As this is an internal failure, no troubleshooting can be conducted. (If there is no problem with the setting work above, the controller may be judged as defective.)