Komatsu — Failure Code in Mechanical System A000N2 (Out-of-rate engine rotation at low idling)

TESTING AND ADJUSTING A000N1 / A000N2 Failure Code in Mechanical System (Out-of-rate engine rotation at high idling) A000N1 Failure Code in Mechanical System A000N2 (Out-of-rate engine rotation at low idling) 20-378 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Engine rotation at high idling out of rate (in mechanical system) — — A000N1 Failure content • Engine rotation above 2,350 rpm was detected for more than 10 seconds, while the engine was running. Response from controller • None in particular • If the failure cause disappears of itself, the engine rotation returns to normalcy.

Phenomenon occurring on machine • There is a possibility that the engine is damaged, if is used continuously without adjustment. Relative information • Input from the engine rotation sensor (rpm) can be confirmed in the monitor function. (Code No. 010: Engine rotation) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Failure in engine mechan- ical system Check if there has been an internal or external factor that would cause the engine to overrun at high idling, and troubleshoot the mechanical system of the engine. 2 Governor • pump controller defective As this is an internal failure, troubleshooting cannot be conducted.

(Unless there is any visible trouble found in the machine, use of the con- troller may be continued as it is) User Code Service Code Failure Code Failure phenomenon Out-of-rate engine rotation at low idling (in mechanical system) — — A000N2 Failure content • Engine rotation below 500 rpm was detected for more than 10 seconds, while the engine was running. Response from controller • None in particular • If the failure cause disappears of itself, the rotation returns to normalcy. Phenomenon occurring on machine • There is a possibility that the engine is damaged, if it is used continuously without adjustment.

Relative information • Input from the engine rotation sensor (rpm) can be confirmed in the monitor function. (Code No. 010: Engine rotation) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Failure in engine mechan- ical system Check if there has been an internal or external factor that would cause the engine to overrun at high idling, and troubleshoot the mechanical system of the engine. 2 Governor • pump controller defective As this is an internal failure, troubleshooting cannot be conducted. (Unless there is any visible trouble found in the machine, use of the con- troller may be continued as it is)