TESTING AND ADJUSTING E-20 E-20 Alarming buzzer cannot be cancelled Electrical Circuit Diagram for Alarming Buzzer Cancellation Switch PC210/240-7K 20-529 Failure information • The alarming buzzer cannot be cancelled. Relative information • Input from the alarming buzzer cancellation switch (ON or OFF) can be confirmed in the monitor function. (Code No. 049:
Monitor input 3) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Alarming buzzer cancellation switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. P03 (female) Alarming buzzer cancellation switch Resistance value Between and Release Above 1 MΩ Depress Below 1 Ω 2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between P02 (female) and P03 (male) Resistance value Below 1 Ω Wiring harness from P03 (male) to J05 to grounding Resistance value Below 1 Ω 3 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Between wiring harness between P02 (female) and P03 (male) and grounding Voltage Below 1 V 4 Monitor panel fault ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. P02 Alarming buzzer cancellation switch Voltage Between and grounding Release 20 – 30 V Depress Below 1 V