TESTING AND ADJUSTING E-21 E-21 "Boom RAISE" is not correctly displayed in monitor function Electrical Circuit Diagram for Boom RAISE PPC Hydraulic Switch 20-530 PC210/240-7K Failure information • "Boom RAISE" is not correctly displayed in the monitor function on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting Boom R hydraul 1 (Interna tion or s ing) AISE PPC ic switch fault l disconnec- hort-circuit- ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.
S06 (male) Boom control lever Resistance value Between and NEUTRAL Above 1 MΩ RAISE Below 1 Ω Disconn ing harn 2 (Discon defectiv with co ection of wir- ess nection or e contact nnector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between C03 (female) and S06 (female) Resistance value Below 1 Ω Wiring harness between S06 (female) and grounding Resistance value Below 1 Ω Ground wiring h 3 (Contac groundi circuit) ing fault of arness t with ng (GND) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) and S06 (female) and grounding Resistance value Above 1 MΩ Short-ci wiring h 4 (Contac circuit) rcuiting of arness t with 24 V ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Between wiring harness between C03 (female) and S06 (female) and grounding Voltage Below 1 V Govern 5 controll or • pump er defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C03 Boom control lever Voltage Between and grounding NEUTRAL 20 – 30 V RAISE Below 1 V