TESTING AND ADJUSTING E-22 E-22 "Boom LOWER" is not correctly displayed in monitor function Electrical Circuit Diagram for Boom LOWER PPC Hydraulic Switch PC210/240-7K 20-531 Failure information • "Boom LOWER" is not correctly displayed in the monitor function on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting Boom LO hydraulic 1 (Internal tion or sh ing) WER PPC switch fault disconnec- ort-circuit- ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.
S02 (male) Boom control lever Resistance value Between and NEUTRAL Above 1 MΩ LOWER Below 1 Ω Disconne ing harne 2 (Disconn defective with con ction of wir- ss ection or contact nector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between C03 (female) and S02 (female) Resistance value Below 1 Ω Wiring harness between S02 (female) and grounding Resistance value Below 1 Ω Groundin wiring ha 3 (Contact groundin circuit) g fault of rness with g (GND) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) and S02 (female) and grounding Resistance value Above 1 MΩ Short-cir wiring ha 4 (Contact circuit) cuiting of rness with 24 V ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Between wiring harness between C03 (female) and S02 (female) and grounding Voltage Below 1 V Governo 5 controlle r • pump r defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C03 Boom control lever Voltage Between and grounding NEUTRAL 20 – 30 V LOWER Below 1 V