TESTING AND ADJUSTING E-31 E-31 Air Conditioner does not work Electrical Circuit Diagram for Air Conditioner 20-544 PC210/240-7K Failure • Th information e air conditioner does not work. Relative • Fo information FU r the electrical circuit diagram inside the air conditioner unit, refer to the section of STRUCTURE AND NCTION - Air Conditioner in this manual. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuse No. 11 fault When the fuse is blown, there is a big possibility that grounding fault occurred in the circuit.
2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between FB1-11 outlet and M26 (male) Resistance value Below 1 Ω Wiring harness between M26 (male) and grounding Resistance value Below 1 Ω 3 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between FB1-11 outlet and M26 (male) and grounding Voltage Above 1 MΩ 4 Air conditioner unit defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. M26 Voltage Between and 20 – 30 V